GA-HFB Air Dryer

Plate Type Refrigerated Air Dryer

GA-HFB Air Dryer

The refrigerating dryer uses the low temperature of the evaporator of the refrigerating system,let's lower the temperature of the compressed air,and then condense the water out,to obtain a dry compressed air source;but cooling the compressed air doesn't necessarily mean the water will be expelled,because a lot of condensed water will be taken away from the refrigerated dryer due to the rapid flow of compressed air, resulting in the phenomenon of excessive water content at the service end;

    Functional Characteristics

    The refrigerating dryer uses the low temperature of the evaporator of the refrigerating system,let's lower the temperature of the compressed air,and then condense the water out,to obtain a dry compressed air source; but cooling the compressed air doesn't necessarily mean the water will be expelled,because a lot of condensed water will be taken away from the refrigerated dryer due to the rapid flow of compressed air, resulting in the phenomenon of excessive water content at the service end;

    GA series air-cooled refrigerating dryer is a new machine developed to solve this problem.the main feature is that the horizontal evaporator is designed with an upright differential configuration.at the bottom of the evaporator is equipped with a refrigerant high-pressure secondary condensation device,this careful design not only makes the cooling system load more stable,the principle of gravity is also used to make the condensed water more difficult to be carried away from the evaporator by the fast-moving compressed air due to the relationship between gravity, so that the condensed water can be completely discharged.

    Correct method of selecting a cold dryer:
    Under different working conditions, the air volume of all kinds of cold drying machines will be different. To choose a suitable cold drying machine, five factors such as the flow rate of compressed air, pressure, inlet temperature, ambient temperature and required pressure dew point must be considered.

    Example: the nameplate of the air compressor indicates that the exhaust volume is 5.2m3 /min, the exhaust pressure is 0.8MPa, the maximum exhaust temperature is 50℃, the ambient temperature of the machine room is 38℃, and the target pressure dew point is 10℃.

    Then: the processing capacity of the cold drying machine = 5.2 Nm3 /min ÷ 0.75 ÷ 1.12 ÷ 1.0 = 6.2 Nm3 /min
    The cold-drying model to be selected is GA-50HFB.

    Product parameters

    Model Air Capacity(Nm³/min SCFM) Air inlet and outlet diameter(DN) Cold media types Compressor power(kw) Weight(KG) Dimensions-L*W*H(mm)
    GA-15HFB 1.7-60 1/2" R-134a 0.32 36 600*360*580
    GA-20HFB 2.6-92 3/4" 0.5 45 645*360*600
    GA-30HFB 3.6-127 1" R-427a 0.59 55 765*380*665
    GA-40HFB 5.2-184 1" 0.7 65 765*380*715
    GA-50HFB 6.5-229 1-1/4" 0.89 75 800*400*865
    GA-60HFB 8-282 1-1/4" 1.08 85 860*450*930
    GA-75HFB 10-353 1-1/2" 1.55 100 900*450*915
    GA-100HFB 13-459 2" 1.91 120 1000*550*1000
    GA-120HFB 16-565 2" 2.52 135 1050*550*1065
    GA-150HFB 19-671 2" 2.7 160 1030*600*1165
    GA-200HFB 23-812 2-1/2" 3.43 235 1170*650*1365
    GA-250HFB 28-988 3" 4.32 250 1210*650*1515
    GA-300HFB 33-1165 3" 4.64 270 1210*650*1615
    GA-350HFB 39-1377 3" 5.2 310 1210*750*1865
    GA-400HFB 45-1589 4"F 6.75 360 1300*900*1715
    GA-500HFB 55-1942 4"F 7.5 430 1300*900*1850
    GA-600HFB 65-2295 5"F 9 520 1300*900*1850
    GA-700HFB 75-2648 5"F 10.1 590 1300*980*2050
    GA-800HFB 80-3001 5"F 11.2 600 1400*1000*2100
    GA-900HFB 95-3354 6"F 13.6 750 1450*1000*2400
    GA-1000HFB 110-3883 6"F 17.7 850 1500*1000*2400